LoadSizer: HVAC Load & BTU-sovelluksen kuvake

LoadSizer: HVAC Load & BTU

Ei lunastettu

Size the AC right — get a room-by-room cooling and heating load estimate in under a…

Tekijä: Duong Nguyen Huu · Tuottavuus
Debuts-pisteet 82UusiAnna ensimmäinen arvio

Miksi odotamme sitä: Clear value and a careful ASHRAE-based method make this a convincing tool for installers, engineers and homeowners.

LoadSizer: HVAC Load & BTU, kuvakaappaus 1LoadSizer: HVAC Load & BTU, kuvakaappaus 2LoadSizer: HVAC Load & BTU, kuvakaappaus 3LoadSizer: HVAC Load & BTU, kuvakaappaus 4LoadSizer: HVAC Load & BTU, kuvakaappaus 5LoadSizer: HVAC Load & BTU, kuvakaappaus 6LoadSizer: HVAC Load & BTU, kuvakaappaus 7LoadSizer: HVAC Load & BTU, kuvakaappaus 8LoadSizer: HVAC Load & BTU, kuvakaappaus 9

Tietoa

Size the AC right — get a room-by-room cooling and heating load estimate in under a minute, built on the ASHRAE CLTD/SCL method instead of a single "BTU per square foot" guess.

Built for installers doing a quick home survey, engineers who want a fast sanity check before a full Manual J, and homeowners who want more than a rule of thumb before buying an AC.

TWO MODES - Quick: floor area, ceiling height, room type, main sun-facing side, insulation level, occupants, top floor or not. Instant estimate. - Detailed: full room construction — exterior walls and windows by orientation (area, U-value, SHGC, shading), roof, ground-floor slab, occupants and activity, lighting, equipment, and outdoor air (ACH).

WHAT YOU GET - Sensible, latent and total cooling load (W, Btu/h, kW, ton) plus SHR, and a heating load for the coldest design day. - A horizontal breakdown by component: walls, windows (conduction and solar shown separately), roof, people, lighting, equipment, outdoor air. - A recommended commercial AC size (5,000-60,000 Btu/h) in Btu/h, ton and HP, rounded up to a size you can actually buy — plus a warning if it's oversized or the load per square foot looks off.

REAL CLIMATE DATA 35 cities across the Americas, Europe, the Middle East and Asia-Pacific, with outdoor design conditions sourced from ASHRAE Climatic Design Conditions — not one flat number for an entire country. Enter your own design climate for anywhere else.

WORKS THE WAY YOU DO - Fully offline. No account, no tracking, no ads. - °C/°F, m²/ft², m/ft, and W/Btu-h/kW/ton/HP, each set independently. - Multiple rooms per project, multiple projects, PDF export. - English, Spanish, Chinese, Portuguese, Japanese, Korean, Vietnamese and Thai.

Free for unlimited Quick estimates and one Detailed room. LoadSizer Pro (one-time purchase, no subscription) unlocks unlimited rooms/projects and PDF export.

LoadSizer uses a simplified ASHRAE Fundamentals 1997 CLTD/SCL/CLF method for fast sizing guidance — not a substitute for a full Manual J or ASHRAE RTS load calculation, and not certified or endorsed by ASHRAE or ACCA.

Ihmisten arvio

Kirjaudu sisään arvioidaksesi tämän sovelluksen. Rehellisyys on tärkeintä.

Ei vielä arvioita. Oletko kokeillut sitä? Anna ensimmäinen arvio.

Lisää Tuottavuus-sovelluksia

Viikon parhaat uudet Tuottavuus-sovellukset

Löydettävyyssignaalit

Miten tekoäly ja ihmiset löytävät sovelluksen LoadSizer: HVAC Load & BTU Debutsissa
TekoälyvalmisOsittain
78 % kuvattu tekoälyn kohdennusta varten
Löydettävissä nytKäytössäRakenteinen data tällä sivulla ja Debuts API

Kerro, mistä pidät. Lähetämme sähköpostia vain, kun jokin uusi vastaa toiveitasi, ja kehittäjät lisäävät usein testaajille edun.

Millaisia sovelluksia
Laitteellani:
Näytä vain
Kuinka usein
Lähetämme vahvistuslinkin. Mitään ei tule, ennen kuin napsautat sitä.